Permit Info

Permit Info

Permit Number: C2400219

Project Name: Tesla Supercharger Station - 5034 Raven Road

Location : 5034 RAVEN RD

Case Type: Commercial Alteration/Upfit

Sub Type:

Status: Issue

Date Issued: 10/17/2024 1:24:01 PM

Child Cases: E2410712 |

Site Addresses
Site Address Suite/Unit # City State Zip Tax Parcel ID
5034 RAVEN RD WS 27105
People
Name Role Company Work Phone Cell Phone Email Comment
HANES MILL ROAD PROPERTIES LLC Property Owner
Contractors
Business Name Contractor Type City State
GLOBAL TECHINICAL SOLUTIONS, LLC (GC) GBNONL KENNER LA
Permit Details
Data Category Description Data
Building Value Electrical: 13000.00
Building Value Upfit: 10000.00
Description of Work Description of Work: Installation of (3) supercharger cabinets, (12) supercharger posts, (1) switchgear assembly with integrated Tesla site controller and primary broadcast unit, (1) utility transformer, (1) meter, and other associated utility equipment, and (1) wireless access point
Building Square Feet Building Sqft: 3400.00
Building Value Declared Value: 140000.00
Property Information and Location Beltway: N/A
Property Information and Location Block: 2040
Property Information and Location Lot(s): 111C
Property Information and Location PIN: 6828-29-7960.000
Property Information and Location Zoning: HB
Property Information and Location CT#: 28.06
Property Information and Location Zoning Jurisdiction: WS
Property Information and Location Municipal Jurisdiction: WS
Property Information and Location Floodplain: X
Property Information and Location Watershed: N/A
Property Information and Location Map Pg: 618886.00
Building Inspector Building Inspector: PUTMAN ALAN
Zoning Inspector Zoning Inspector: DENTON JESSICA
Office Information-Commercial Building Fire Fee Y
Permits Required Electrical Y
Tasks
Task Description Result Description Date Scheduled Date Completed Completed By Comments
Plan Submittal Checklist - Comm ACCEPTED 3/21/2024 3/20/2024 REBECCA GEARREN View Comments
Plan Review Fees Paid PAID_ 3/21/2024 3/21/2024 PLL admin View Comments
Building Review APPROVED 4/5/2024 3/22/2024 PLL admin View Comments
Electrical Review APPROVED 4/5/2024 3/25/2024 PLL admin View Comments
Erosion Review APPROVED 4/5/2024 3/21/2024 PLL admin View Comments
Fire (City) Review APPROVED 4/5/2024 3/27/2024 PLL admin View Comments
Fire (County) Review WAIVE 4/5/2024 7/16/2024 PLL admin View Comments
Health Department Review WAIVE 4/5/2024 7/16/2024 PLL admin View Comments
Landscaping Review WAIVE 4/5/2024 7/16/2024 PLL admin View Comments
Mechanical Review WAIVE 4/5/2024 3/22/2024 PLL admin View Comments
Plumbing Review WAIVE 4/5/2024 3/22/2024 PLL admin View Comments
Refrigeration Review WAIVE 4/5/2024 3/22/2024 PLL admin View Comments
Utilities Review APPROVED 4/5/2024 3/22/2024 PLL admin View Comments
Zoning Review FAILED 4/5/2024 3/21/2024 PLL admin View Comments
Zoning Review FAILED 4/5/2024 4/19/2024 PLL admin View Comments
Zoning Review APPROVED 5/3/2024 7/15/2024 PLL admin View Comments
Driveway Review WAIVE 4/5/2024 3/22/2024 PLL admin View Comments
Administrative Review APPROVED 7/19/2024 10/11/2024 REBECCA GEARREN View Comments
Plans Delivered & Forms Completed COMPLETE_ 10/14/2024 10/16/2024 SARAH BOND View Comments
Issue Permit ISSUE 10/17/2024 10/17/2024 PLL admin View Comments
Footing Inspection View Comments
Foundation Inspection View Comments
Slab Inspection View Comments
Framing Inspection View Comments
Exterior Framing Inspection View Comments
Insulation Inspection View Comments
Fire Inspection View Comments
Driveway Inspection View Comments
Zoning Inspection View Comments
Health Dept Septic Sewer Inspection View Comments
Final Inspection View Comments
Issue Certificate of Occupancy View Comments
Inspection Requests
Inspection Type Inspection Date Requested By Status
Conditions
Condition Description Date Applied Date Completed
ACCESSORY USE - NO BUILDING 10/16/2024 10/16/2024
All work has stopped on the case. 4/18/2025
Flags
Flag Description Date Applied Date Completed
All work has stopped on this case. 4/18/2025
Notes
Note
Fees
Fee Description Fee Amount Balance Due Date Created
Zoning Review and Inspection $100.00 $0.00 3/20/2024 12:31:37 PM
Pre-Plan Alteration/Upfit $100.00 $0.00 3/20/2024 12:31:38 PM
Fire Permit Fee $40.00 $0.00 3/20/2024 12:31:38 PM
Commercial Alteration/Upfit (Declared) $492.00 $0.00 3/20/2024 12:31:38 PM
Cell Tower $0.00 $0.00 3/20/2024 12:31:39 PM
Payments
Fee Description Fee Amount Payment Amount Payment Date Payment Method Reference
Pre-Plan Alteration/Upfit $100.00 $100.00 3/21/2024 Credit Card 1339921879
Zoning Review and Inspection $100.00 $100.00 10/15/2024 INOVAH
Commercial Alteration/Upfit (Declared) $492.00 $492.00 10/15/2024 INOVAH
Fire Permit Fee $40.00 $40.00 10/15/2024 INOVAH
Attachments
Image Name Date Created
RE_ [EXTERNAL] Project 1282298 Declined_ Tesla - 5034 Raven Road Winston-Salem, NC.pdf 3/26/2024 4:53:49 PM
Winston-Salem NC and Forsyth County - Certificate.pdf 10/16/2024 5:32:18 PM
Permit C2400219 signed permit TESLA winston salem.pdf 10/16/2024 7:57:52 PM
Workers Compensation Coverage Affidavit.pdf 10/16/2024 7:58:10 PM